Actuators from pi safety
QT.Ex-M
QT.Ex-M, electric actuators explosion-proof ATEX / IECEx
Ex actuator with return spring
- ATEX / IECEx certified
- Integrated connection box
- Ambient temperature -40…+70 °C
- Optional fail-safe position / return spring
- Optional control / feedback 0…10 V; 4…20mA
- IP66, very high corrosion resistance, weatherproof
- For use in zones 1, 2, 21, 22
QT.Ex-M
QT.Ex-M, electric actuators explosion-proof ATEX / IECEx
Ex actuator without spring return
- ATEX / IECEx certified
- Integrated connection box
- Ambient temperature -40…+70 °C
- Optional fail-safe position / spring return
- Optional control / feedback 0…10 V; 4…20mA
- IP66, very high corrosion resistance, weatherproof
- for use in zones 1, 2, 21, 22
QT.Nc-M
QT.Nc-M, electric actuators
Nc actuator with spring return
- Integrated connection box
- Ambient temperature -40…+70 °C
- Optional fail-safe position / spring return
- Optional control / feedback 0…10 V; 4…20mA
- IP66, very high corrosion resistance, weatherproof
QT.Nc-M
QT.Nc-M, electric actuators
Nc actuator without spring return
- Integrated connection box
- Ambient temperature -40…+70 °C
- Optional fail-safe position / spring return
- Optional control / feedback 0…10 V; 4…20mA
- IP66, very high corrosion resistance, weatherproof
TR.EX Transducer
TR.EX Transducer
- Specification:
- II2(1)G Ex eb mb ib [ia Ga] IIC T4 Gb
- II2(1)D Ex tb ib [ia Da] IIIC T130°C Db
- Universal transducer for mounting in zones 1 / 2 / 21 / 22
- Ambient temperature -40…+70°C
- IP66
- Temperature class T4 for all gases and dusts
- Parameters can be set on site
SW.Ex Switching amplifier
SW.Ex Switching amplifier
- Specification:
- II2(1)G Ex eb mb ib [ia Ga] IIC T4 Gb
- II2(1) D Ex tb ib [ia Da] IIIC T130°C Db
- Universal Ex switching amplifier for installation in Zone 1 / 2 / 21 / 22
- Two configurable switching points / relay outputs
- Ambient temperature -40…+70 °C
- IP66
- Temperature class T4 for all gases and dusts
- Adjustable hysteresis
- Parameters can be set on site
TR.Nc Transducer
TR.Nc Transducer
- Switching amplifier with relay output
- Two configurable switching points
- Ambient temperature -40…+70 °C
- IP66
- Parameters can be set on site; display
- Stainless steel / polymer compound material for maximum corrosion resistance
SW.Nc Switching amplifier
SW.Nc Switching amplifier
- Switching amplifier with relay output
- Two configurable switching points
- Ambient temperature -40…+70 °C
- IP66
- Parameters can be set on site; display
- Stainless steel / polymer compound material for maximum corrosion resistance
Accessories and calibration services
We have a wide range of additional supplies to facilitate installation of our products. Please contact our customer service for your individual needs, also for accessories not listed below. In addition, we also offer calibration services for our devices.
Accessories actuators
WS.Va-M
Additional top made of stainless steel to protect against adverse conditions, vandalism, etc.
TJ.Va-M
Additional stainless steel housing enables operation of the drive down to -60 °C
KR.Vz-12
Clamp and anti-rotation device for mounting on round axles (10-20 mm) and square axles (VK 10-16 mm), galvanized
AH-12-08
Adapter sleeve square 12 mm to square 08 mm
AH-12-10
Adapter sleeve square 12 mm to square 10 mm
AH.-12-11
Adapter sleeve square 12 mm to square 11 mm
LV.Qt-….
Adaptation to rotary fittings according to order code …
LT.Qt-….
Linear conversion for QT drives according to order code …
Accessories actuators
MA. pa-06
Connection set for pressure sensors, comprising connection nipple, pressure hose and fastening screws for IY.Nc-P…,
IY.Ex-P…, IR.Nc-P… and IR.Ex-P…
MA. pa-06
Connection set for pressure sensors, comprising connection nipple, pressure hose and fastening screws for IY.Nc-P…,
IY.Ex-P…, IR.Nc-P… and IR.Ex-P…
TH.VA-….
Immersion sleeve, stainless steel, G ½” various lengths
SC.Pu-01
M12 sensor cable, 5-pin, shielded, 1 meter
SC.Pu-05
M12 sensor cable, 5-pin, shielded, 5 meters
SC.Pu-0SC.Pu-10
M12 sensor cable, 5-pin, shielded, 10 meters
LK.Pa
Level kit for pressure sensors
SR.Va-200
Pitot tube for recording volume flow, l=200 mm
CS.Ms-M12
M12 adapter set for connection to on-site cables
Frost protection ATEX
FS.Ex.03
Capillary frost protection, adjustable, length 3 meters, including fastening material, in combination with BS.Ex
FS.Ex.06
Capillary frost protection, adjustable, length 6 meters, including fastening material, in with BS.Ex
BS.Ex
Barrier for control cabinet mounting for FS.Ex
Accessories calibration
KA.Pi
Calibration of humidity, temperature and pressure in our own calibration laboratory with certificate (on request)
Pi Safety Components GmbH & Co. KG
Mühlenweg 2
D-96358 Teuschnitz