Sensor Switching Amplifier SW.Nc Pi Safety

 

  • Manufacture: Pi Safety Components
  • Switching amplifier with relay output
  • Two configurable switching points
  • Ambient temperature -40…+70 °C
  • IP66
  • Parameters can be set on site; display
  • Stainless steel/polymer compound material for maximum corrosion resistance
  • Adjustable hysteresis
  • LED status display
  • Easy installation
  • 24VAC/DC
  • for IR.Nc sensors
  • Made In: Germany

Mô tả

Sensor Switching Amplifier SW.Nc Pi Safety

Bộ Khệch đại chuyển mạch SW.Nc Switching Amplifier

SW.Nc Switching Amplifier

 

Specification Sensor Switching Amplifier SW.Nc Pi Safety:

  • Manufacture: Pi Safety Components
  • Switching amplifier with relay output
  • Two configurable switching points
  • Ambient temperature -40…+70 °C
  • IP66
  • Parameters can be set on site; display
  • Stainless steel/polymer compound material for maximum corrosion resistance
  • Adjustable hysteresis
  • LED status display
  • Easy installation
  • 24VAC/DC
  • for IR.Nc sensors
  • Made In: Germany

IR.Nc Sensors

  • Intelligent sensor system for connection (M12 plug) to SW.Nc universal switching amplifier
  • Stainless steel or stainless steel/polymer compound material for superior corrosion resistance
  • Room sensor for direct connection
  • Other sensors using M12 sensor cable (1 m included in delivery, other lengths on request)
  • in combination with SW.Nc universal switching amplifier

SW.Nc – Switching relay

SW.Nc Switching amplifier with relay output

 

IR.Nc – Temperature/Humidity

IR.Nc-RT Room sensor temperature; measuring range -40…+125 °C
IR.Nc-RH Room sensor temperature / humidity; measuring range -40…+125 °C; 0…100% rF
IR.Nc-DT-050 Duct sensor temperature; l = 50 mm; measuring range -40…+125 °C
IR.Nc-DH-050 Duct sensor humidity; l = 50 mm; measuring range -40…+125 °C; 0…100% rF
IR.Nc-DT-100 Duct sensor temperature; l = 100 mm; measuring range -40…+125 °C
IR.Nc-DH-100 Duct sensor humidity; l = 100 mm; measuring range -40…+125 °C; 0…100% rF
IR.Nc-DT-200 Duct sensor temperature; l = 200 mm; measuring range -40…+125 °C
IR.Nc-DH-200 Duct sensor humidity; l = 200 mm; measuring range; 0…100% rF

 

IR.Nc – Differential pressure

IR.Nc-P-0060 Differential pressure sensor -60…+60 Pa
IR.Nc-P-0100 Differential pressure sensor -100…+100 Pa
IR.Nc-P-0250 Differential pressure sensor -250…+250 Pa
IR.Nc-P-0600 Differential pressure sensor -600…+600 Pa
IR.Nc-P-1000 Differential pressure sensor -1000…+1000 Pa
IR.Nc-P-2500 Differential pressure sensor -2500…+2500 Pa
IR.Nc-P-4000 Differential pressure sensor -4000…+4000 Pa
IR.Nc-P-10000 Differential pressure sensor -10000…+10000 Pa

 

IR.Nc – Volume flow rate

IR.Nc-V-0100 Differential pressure sensor -100…+100 Pa
IR.Nc-V-0250 Differential pressure sensor -250…+250 Pa
IR.Nc-V-0600 Differential pressure sensor -600…+600 Pa
IR.Nc-V-1000 Differential pressure sensor -1000…+1000 Pa
IR.Nc-V-2500 Differential pressure sensor -2500…+2500 Pa

 

Đánh giá

Chưa có đánh giá nào.

Hãy là người đầu tiên nhận xét “Sensor Switching Amplifier SW.Nc Pi Safety”